Please use this identifier to cite or link to this item:
https://www.arca.fiocruz.br/handle/icict/24079
APLICAÇÃO DO MÉTODO DE ANÁLISE HIERÁRQUICA MAH, VISANDO A UTILIZAÇÃO DE POÇOS COM ALTO TEOR NATURAL DE ION FLUORETO, QUANDO ÚNICA FONTE DE ÁGUA PARA CONSUMO HUMANO
Poços
Método de Análise Hierárquica
Tratamento Avançado da Água
Water treatment
Water sources
Wells
Hierarchical Analysis Method
Advanced Water Treatment
Campos, Luís Francisco | Date Issued:
2005
Alternative title
Application of the analytic hierarchy process aiming at the utilization of wells with high natural content of ion fluoreto, when only spring of equal water consume humanAuthor
Advisor
Affilliation
Fundação Oswaldo Cruz. Escola Nacional de Saúde Pública Sergio Arouca. Rio de Janeiro, RJ, Brasil.
Abstract in Portuguese
A Portaria n. 518, de 25 de março de 2004, do Ministério da Saúde, estabelece os Procedimentos e Responsabilidades Relativas ao Controle e Vigilância da Qualidade da Água para Consumo Humano e seu Padrão de Potabilidade. O Valor Máximo Permitido (VMP) para a concentração de íons fluoreto deve observar a legislação específica respeitando o VMP da Tabela (1,5 mg/l). No Brasil, diversas regiões apresentam águas subterrâneas com concentração natural de fluoretos superior ao VMP, contribuindo para o agravamento da saúde daqueles que as consomem podendo acarretar a fluorose dentária. Este estudo foi baseado na revisão de literatura de alternativas (processos, técnicas) de desfluoretação, sobre as quais se procurou construir um modelo de decisão para a escolha de uma delas, visando o tratamento da água obtida de manancial subterrâneo, quando única fonte hídrica, em comunidades em zonas rurais, cuja análise química apresenta concentração natural de íons fluoreto superior ao permitido pela legislação vigente. O modelo de decisão utilizado foi baseado no Método de Análise Hierárquica (MAH) ou Analytic Hierarchy Process (AHP), que é uma ferramenta de auxílio à tomada de decisão por múltiplos critérios desenvolvida por Thomas L. Saaty no final dos anos 70. (...) Das diversas alternativas de desfluoretação analisadas o carvão de osso (CO) e a alumina ativada (AA) foram considerados como ótimos adsorventes e os mais utilizados; entretanto, o monitoramento da operação foi considerado bastante oneroso. Os resultados da aplicação do Método de Análise Hierárquica (MAH) permitiram a indicação da osmose reversa (OR) como melhor alternativa para a redução do excesso natural de íons fluoreto nas águas subterrâneas para consumo humano.
Abstract
The Regulation N. 518, from March 24 of 2004, by the State Departmentof Health, settles the Proceedings and Responsibilities Relating to Control andSurveillance of Water Quality for Human Ingestion and it s Potability Standard. The Maximum Contaminant Level (MCL) for the fluoride ion concentration mustfulfil the specific legislation according to the MCL from the Chart (1,5 mg/l). In Brazil, many regions present underground water with a natural fluorideconcentration higher than the MAV, aggrieving the health of those who drink it, possibly causing Dental Fluorosis. This study was based on the revisal of defluoridationalternatives / proceedings / techniques literature, over which was attempted to builda decision model for the choice of one of them, aiming at the treatment of thewater obtained from underground fountainhead, when it s the only water source atrural areas and whose chemical analysis presents a natural fluoride ionconcentration superior than the allowed by the present legislation.The decision model used was based on the Analytic Hierarchy Process (AHP), which is a supporting tool to the decision making by multiple criteria, developed by Thomas L. Saaty at the late 70 s. The following criteria were considered: (i) physical-chemical characteristics of raw water, emphasizing the fluoride ion concentration and theamount to be treated; (ii) physical-chemical characteristics of the treated water, emphasizing the optimal final fluoride ion concentration; (iii) implementation expenses; and (iv) production, operation and maintenance expenses. From the many defluoridation alternatives analyzed, the bone coal and the activated alumina were considered excellent adsorbents and the most frequentlyused. However, the operation monitorament was considered too onerous. The results of the application of the Analytic Hierarchy Process (AHP) enabled the indication of the reverse osmosis as the best alternative for thereduction of the natural surplus of fluoride ion on underground water for humanuse. Reverse Osmosis membranes can be successfully used for the treatment of underground water to the desired purity water level, as they remove up to 95 percent of fluoride present in water and also take care of other ions present in water.
Keywords in Portuguese
DesfluoretaçãoPoços
Método de Análise Hierárquica
Tratamento Avançado da Água
Keywords
DefluorinationWater treatment
Water sources
Wells
Hierarchical Analysis Method
Advanced Water Treatment
Share