Author | Martins, Heliana Figueiredo | |
Author | Pinto, Douglas Pereira | |
Author | Nascimento, Viviane de Assis | |
Author | Marques, Marlice Aparecida Sipoli | |
Author | Amendoeira, Fábio Coelho | |
Access date | 2015-10-02T17:49:31Z | |
Available date | 2015-10-02T17:49:31Z | |
Document date | 2014 | |
Citation | MARTINS, H. F. Development of a HPLC/MS/MS methodology for determining 3-O-methyldopa in human plasma and its application in a bioequivalence study. Rev. Inst. Adolfo Lutz, São Paulo, v. 73, n. 1, p. 96-105, 2014. | pt_BR |
ISSN | 0073-9855 | |
URI | https://www.arca.fiocruz.br/handle/icict/11877 | |
Abstract in Portuguese | Uma metodologia específica, simples e sensível baseado em HPLC/MS/MS foi desenvolvida e validada para realizar a determinação de 3-o-metildopa, o principal metabolito da dopamina, em plasma humano.
A separação foi realizada em coluna analítica Atlantis T3 C18 (5 μm; 150 x 4,6 mm i.d.), utilizando-se uma fase móvel composta por uma solução de água e metanol (85:15, v/v), e contendo 0,05 % de ácido fórmico. A extração do analito e da amostra padrão interno foi executada utilizando-se uma simples precipitação proteica no plasma com ácido perclórico. A detecção foi realizada por meio de espectrômetro de massa
triplo quadrupolo, em modo de monitoramento de reações múltiplas (MRM) positivo. A transição monitorizada foi m/z 212,0 - m/z 166,0 para 3-O-metildopa e m/z 227,1 - m/z 181,0 para carbidopa (padrão interno). As curvas de calibração foram lineares na faixa de 50 a 4000 ng/mL para 3-O-metildopa. A metodologia apresentou boa precisão e exatidão de acordo com os critérios para análises biomédicas e esta foi aplicada com sucesso no estudo de bioequivalência de duas formulações contendo levodopa + benserazida (200 + 50 mg) em amostras de plasmas humanos. | pt_BR |
Language | eng | pt_BR |
Publisher | Instituto Adolfo Lutz | pt_BR |
Rights | open access | pt_BR |
Subject in Portuguese | 3-O-metildopa | pt_BR |
Subject in Portuguese | HPLC-ESI-MS/MS | pt_BR |
Subject in Portuguese | Bioequivalência | pt_BR |
Subject in Portuguese | Plasma | pt_BR |
Subject in Portuguese | Farmacocinética | pt_BR |
Title | Development of a HPLC/MS/MS methodology for determining 3-O-methyldopa in human plasma and its application in a bioequivalence study | en |
Alternative title | Desenvolvimento de metodologia baseada em HPLC/MS/MS para a determinação de 3-O-metildopa em plasma humano e sua aplicação a estudos de bioequivalência | pt_BR |
Type | Article | pt_BR |
DOI | http://dx.doi.org/10.18241/0073-98552014731593 | |
Abstract | A simple, sensitive and specific HPLC/MS/MS methodology was developed and it was validated for determining 3-O-methyldopa, the major metabolite of dopamine, in human plasma. The separation was achieved on Atlantis T3 C18 analytical column (5 μm; 150 x 4.6 mm i.d.) using a mobile phase consisted of a solution of water and methanol (85:15, v/v) and containing formic acid 0.05%. The extraction from the analyte and the internal standard sample was performed using a simple protein plasma precipitation with perchloric acid. The detection was conducted on a triple quadrupole tandem mass spectrometer with a positive multiple reaction monitoring mode (MRM). The monitored fragmentation transitions were m/z 212.0 - m/z 166.0 for 3-O-methyldopa and m/z 227.10 - m/z 181.0 for carbidopa (internal standard). The calibration curves were linear in the range of 50–4000 ng/mL for 3-O-methyldopa. The methodology presented a good precision and accuracy in accordance to the criteria for biomedical analysis. And it was successfully applied to the bioequivalence study of two formulations levodopa + benserazide (200 + 50 mg) in plasma samples from healthy human volunteers, following the ANVISA guidelines. | en |
Affilliation | Fundação Oswaldo Cruz. Laboratório de Farmacocinética. Rio de Janeiro, RJ, Brasil. | pt_BR |
Affilliation | Fundação Oswaldo Cruz. Laboratório de Farmacocinética. Rio de Janeiro, RJ, Brasil. | pt_BR |
Affilliation | Fundação Oswaldo Cruz. Laboratório de Farmacocinética. Rio de Janeiro, RJ, Brasil. | pt_BR |
Affilliation | Universidade Federal do Rio de Janeiro. Instituto de Química. Departamento de Química Analítica. Rio de Janeiro, RJ, Brasil. | pt_BR |
Affilliation | Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Farmacologia e Toxicologia. Rio de Janeiro, RJ, Brasil. | pt_BR |
Subject | 3-O-methyldopa | en |
Subject | HPLC-ESI-MS/MS | en |
Subject | Bioequivalence | en |
Subject | Plasma | en |
Subject | Pharmacokinetics | en |
DeCS | Metildopa | pt_BR |
DeCS | Cromatografia Líquida de Alta Pressão | pt_BR |
DeCS | Equivalência Terapêutica | pt_BR |
DeCS | Plasma | pt_BR |
DeCS | Farmacocinética | pt_BR |